• Cable gland with integrated ventilation
  • High degree of protection
  • Easy to install
  • Integrated strain relief
  • Waterproof filter
  • Large clamping range


  • Pressure differentials in enclosures with a high degree of protection are a result of internal and external temperature changes. In the case of negative pressure or partial vacuum, dust and humidity can enter the enclosure through the door seal. When the air inside the enclosure cools down, condensation may occur because the humidity cannot escape the enclosure. The innovative and easy-to-install ventilation cable gland DAK 284 enables secure cable entry into an enclosure with simultaneous pressure compensation (protection type IP66 / IP67). Even with a slight overpressure, a waterproof filter inside the gland allows the humidity to escape whilst blocking water and dirt from entering the enclosure.
    1 - 3 of 3 | Results Per Page | View | Unit of Measure
    1 

    Part #

    Thread Size M

    Thread Length L

    Cable Dia. Clamping Range D

    Torque Lock Nut

    Air Permeability

    Weight

    3D & 2D CAD

    Sort by
    N/A M20 x 1.5 N/A 0.39 inches (10 mm) N/A 0.24 - 0.48 inches (6 - 12 mm) N/A 5 Nm N/A 40 l/h N/A 0.46 oz. (13 g) N/A
    N/A M16 x 1.5 N/A 0.39 inches (10 mm) N/A 0.16 - 0.32 inches (4 - 8 mm) N/A 2 Nm N/A 25 l/h N/A 0.28 oz. (8 g) N/A
    N/A M12 x 1.5 N/A 0.31 inches (8 mm) N/A 0.16 - 0.32 inches (4 - 8 mm) N/A 2 Nm N/A 25 l/h N/A 0.25 oz. (7 g) N/A
    1 - 3 of 3 | Results Per Page | View | Unit of Measure
    1